What was found
INSPECTION TYPE:3C, CENTER CARGO LONGERON 44R HAS CORROSION AT STA. 5-118.REPAIRED CORRODED LONGERON 44R BETWEEN STA. 5-93 & 5-123 IAW EA 011-5310-01-A9466 REV. I/R AND EO MD11-5310-82764-A. (MAJOR)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION TYPE:3C, CENTER CARGO LONGERON 44R HAS CORROSION AT STA. 5-118.REPAIRED CORRODED LONGERON 44R BETWEEN STA. 5-93 & 5-123 IAW EA 011-5310-01-A9466 REV. I/R AND EO MD11-5310-82764-A. (MAJOR)