As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
INSPECTION TYPE:C4UPPER CTR AUX TANK HAS CRACK ON A INCOMING SPLCE REPAIR ON STRINGER 48 REPAIR ZEE AT SPLICE LOCATION STA XCW-17 AND XCW=17.REMOVED,FAB, REPAIRED THE CRACK ON STRINGER 48 REPAIR ZEE AT STA XCW=-17 AND XCW=17 IAW VTSAA EA 011-5710-01-A9491 REV I/R AND UPS EO MD11-5710-82992-A AND FAA FORM 8100-9 SIGNED BY M. NOMURA (AR-605404) DATED 04/28/16 (MAJOR)