As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
INSPECTION TYPE:N/A**SDR FILED OPEN** L1 ENTRY DOOR OPEN ,SYNOPTI C SHOW DOOR CLOSED ,ALSO NO ASSOCIATED EICAS MSG SAYING DOOR OPEN. 1.PER MEL 52-73-1-0-1 RLS A/C & DMP C/W . 2.DI M774966 UPDATE & PLACARD INSTALL. R/R SWITCH 529 IN REF TO WDM 52-71-01. OPS NORMAL IN REF TO AMM 52-71-00.