What was found
INSPECTION TYPE:CMDCC AT FR74 AND Y2127.5 FLOOR PANEL SUPPORT STRUCTURE CRACKEDREMOVED FABBRICATED AND INSTALLED IAW SRM 51-40-21
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION TYPE:CMDCC AT FR74 AND Y2127.5 FLOOR PANEL SUPPORT STRUCTURE CRACKEDREMOVED FABBRICATED AND INSTALLED IAW SRM 51-40-21