What was found
INSPECTION TYPE:N/A**SUPPLEMENTAL SDR** RIGHT FUSELAGE SKIN DENT FORWARD OF FR 58, BELOW S-31R DAMAGE.C/W UPS E/O A300-5330-83246B PRELIM #2 PARA 6 C (5) (6) (7) (8) IAW PART 6, 51-10-08 & 51-10-01, PRELIM #3 THRU STEP 18, STEPS 19 AND 20. HFEC DONE PER A300 NTM 51-10-08 AND 51-10-01, NO CRACKS NOTED AT THIS TIME, VERIFIED DAMAGE REMOVED. ACCOMPLISHED GVI INSP. COMPLETED REPAIR IAW EO A300-5330-83246-B.