What was found
INSPECTION TYPE:SEG1AFT PIT FRAME UPPER J ANGLE DENTED AT STA 1260 STR 26LREPAIR PER UPS RCD 251322 AND SRM 53-00-07-2R-6 DETAIL VI
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION TYPE:SEG1AFT PIT FRAME UPPER J ANGLE DENTED AT STA 1260 STR 26LREPAIR PER UPS RCD 251322 AND SRM 53-00-07-2R-6 DETAIL VI