What was found
INSPECTION TYPE:NA**SUPPLENTAL SDR** AT 1 H 43 MIN LH AFT FUEL PUMP C/B POPPED.1.R/R LH MAIN FUEL TANK AFT BOOST PUMP IAW AMM 28-22-03. 2. FUEL BOOST PUMP OPERATIONAL TEST SATIS. PN ON/OFF 5006003D/5006003S SN ON/OFF 3981/725 REF IPC 28-22-03-01-060U
INSPECTION TYPE:NA**SDR FILED OPEN** **ATB** **CURRENTLY OOS** AT 1 H 43 MIN LH AFT FUEL PUMP C/B POPPED. 1.R/R LH MAIN FUEL TANK AFT BOOST PUMP IAW AMM 28-22-03. 2. FUEL BOOST PUMP OPERATIONAL TEST SATIS. PN ON/OFF 5006003D/5006003S SN ON/OFF 3981/725 REF IPC 28-22-03-01-060U