As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
INSPECTION TYPE:SEG1** SUPPLEMENTAL SDR **AFT LOWER CARGO PIT BETWEEN FRAMES 1400-1420 AND BETWEEN STR 29L AND 30 LOWER BUILDGE INTERCOSTAL IS EXPOLIATED ON LOWER LIP ON TOP OF SKIN.REMOVED CORRODED INTERCOSTAL AND INSTALLED REPLACEMENT INTERCOSTAL PER SRM 51-40-02.