As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
INSPECTION TYPE:N/AA/C LOST POWER DURING LIGHTNING STORM AND WILL NOT FULLY START BACK UP. BURNING ELECTRICAL SMELL ON FLIGHT DECK. TWO ECAM MSG'S "AC ESS BUS OFF" & "AC EMER BUS OFF".R/R RECTIFIER UNITS 3XD & 5XH PER ESPM 20-46-50. ACCOMPLISHED OPERATIONAL TEST OF A/C MONITORING & INDICATION IAW AMM 24-27-00-0501. OPS CK NORMAL. NO FAULTS NOTED REF IPC 24-52-0802B & 24-53-08-02A