What was found
INSPECTION TYPE:3CCENTER CARGO COMPARTMENT LONGERON 46R SPLICE FITTING CRACK AT STA.1671.REMOVED,FABRICATED AND REPLACED CRACKED SPLICE IAW DWG AFA7113 AND SRM 51-33-01 (MINOR).
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION TYPE:3CCENTER CARGO COMPARTMENT LONGERON 46R SPLICE FITTING CRACK AT STA.1671.REMOVED,FABRICATED AND REPLACED CRACKED SPLICE IAW DWG AFA7113 AND SRM 51-33-01 (MINOR).