What was found
INSPECTION TYPE:N/A**ATB** - **EMERGENCY DECLARED** LEVEL AT 33,000' RECEIVED A LEVEL 1 TNK 1 TIP TRAPPED AND LEVEL 1 TNK 1 FUEL QTY LO. 5600 LBS TRAPPED IN TIPTANK AIR TURN BACKTRBLSHT FUEL TRANSFER SCHEDULED REF MD11 FIM 28 14 16 00 SHT 1 REMOVED & REPALCED STANDARD ELEC. MOD RF MD11 M/M CHAP 28 41 92 401 OPS CHKED SYSTEM OK REMOVED & REPLACED FUEL SYST COTNROLLER REF PRECUAITON REF MD11 M/M 28 08 01 . RTS CHKED OK PERFORMED TNK COMP FUEL GRAVITY & JET PUMP