As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
INSPECTION TYPE:3CR/H I/B FLAP AFT HINGE FITTING #7 HOLE HAS PITTING AT STA XW=254, YW=495.96 AND ZW=-28-941.REPAIRED THE AFT HINGE #7 HOLE IAW VT-SAA EA 011-5740-01-A9719 REV I/R DATED 10/07/22 AND UPS EO MD11-5750-84954-A DATED 10/07/22 AND FAA FORM 8100-9 SIGNED BY S.KANG (AR-605677) DATED 10/05/22 (MINOR)