What was found
INSPECTION TYPE:NA*SDR FILED OPEN* L1 DOOR INTERMITTENLY WORKING ELECTRICALLY. C/W DMP. DEFERRED L1 DOOR PER MEL 52-10-1-2-0-1. R&R LEFT FWD DOOR ACTUATOR RELAY (R2-177) AND LH FWD DOOR LOCK PWR RELEASE RELAY (R2-5324) IAW WDM 52-11-01, SWPM 20-20-03. PERFORMED OPSK IAW AMM 52-11-02-201, OPSCKS GOOD AT THIS TIME.