What was found
MAIN ENTRY SLIDE ARMING HANDLE REQUIRES CONSIDERABLE PRESSURE TO FULLY DISARM. DEFERRED L1 DOOR SLIDE PER MEL 52 11 01 2 3 DMP ACCOMPLISHED PLACARDS INSTALLED ASSIGNED TO. R/R GIRT BAR PER AMM 25-61-21-0401, CHECKED ADJUSTMENT OF GIRT BAR PER AMM 52-10-30-0501. FOUND ADJUSTMENT OK. CLEANED & LUBRICATED SLIDE RELEASE MECH. DOOR OPERATES NORMAL