What was found
INSPECTION TYPE:SVLIGHTNING STRIKE FR 38 1" ABOVE STR 52LH FOUND TO BE OUT OF LIMITSREPAIRED PER SRM 53-10-12 FIGURE 208
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION TYPE:SVLIGHTNING STRIKE FR 38 1" ABOVE STR 52LH FOUND TO BE OUT OF LIMITSREPAIRED PER SRM 53-10-12 FIGURE 208