As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
SLIDE WARNING LIGHT NOT ILLUMINATING DURING TEST. BUZZER WORKS. SLIDE WARNING LIGHT DEFERRED PER MEL 52-73-01-1. CONTROL NUMBER M806229 ASSIGNED. NO DMP. PLACARD INSTALLED.RESET AUTONOMOUS-STBY POWER SUPPLY UNIT. SYS OPS NORMALLY M/M 52-73-18-0401 AND ADT AND TEST M/M 52-73-00-0501 THIS CLEARS M 806229 PLACARD REMOVED