As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
INSPECTION TYPE:C3R/H O/B FLAP I/B AFT HINGE #7 LUG BORE HAS CORROSION AT STA XW=-486.403, YW=589.366.REPAIRED CORRODED HINGE AT THE R/H O/B FLAP I/B AFT #7 LUG BORE AT STA XW=-486.403, YW=589.366 IAW VTSAA EA 011-5740-01-A9932 I/R AND UPS EO MD11-5750-86681-A DATED 04/28/23 (MINOR)