What was found
INSPECTION TYPE:N/ACORROSION FOUND ON MAIN CABIN FLOOR PANEL AT STA Y=386 - Y=421.578 AND BETWEEN X= 27.5 TO X=42REPLACED MAIN CABIN FLOOR PANEL AT STA Y=386 TO Y=421.578 , X=27.5 TO X=42 IAW DWG ABA8304 AND SRM 51-31-01,SRM 51-33-01 AND USING ORIGINAL PART AS SAMPLE PER UPS GMM 09-10. MINOR