As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
LEFT MAIN ENTRY DOOR WILL NOT OPEN ELECTRICALLY FROM EITHER SIDE. DEFERRED LEFT MED IAW MEL 52-10-3-1-2-1-2. R/R L1 FWD PASS DOOR LOCK PIN RELEASE SOLENOID PER AMM 52-10-06. OPS CHECK GOOD REF AMM 52-11-02. THIS CLEARS M809103. PLACARD REMOVED. IPC 52-11-07.