As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
*** EMERGENCY DECLARED *** LEFT HYD QTY AND LEFT ENG HYD PUMP PRESS LIGHT INSPECTION C/W. FOUND LINE IN PYLON CONNECTING TO ENG DRIVEN PUMP CASE DRAIN PRESS FILTER MODULE LOOSE. IPC 29-11-17-02 ITEM 905M. TIGHTEN LINE PER STANDARD PRACTICE MANUAL 20-11-00-912-001. SERVICED LH HYD SYS IAW AMM 12-12-01-613-015. ENG RUN C/W PER AMM 71-00-00-215-053-P00 NO.2A NO LEAKS NOTED.