As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
INSPECTION TYPE:3CR/H I/B FLAP O/B HINGE LOWER O/B LUG HOLE #6 IS OUT OF LIMITS AT STA XW=-254.REPAIRED HINGE ASSY AT THE R/H I/B FLAP O/B HINGE AT STA XW=-254 IAW VTSAA EA 011-5740-01-A9988 I/R, UPS EO MD11-5750-87385-A DATED 07/07/23 AND FAA FORM 8100-9 SIGNED BY S. KANG (AR-605677) DATED 07/06/23 (MINOR)