CREW ENTRY DOOR TOP COVER MISSING AFT UPPER BOLT/WASHER.RE-ATTATCHED SHIMS ON BOTH SIDES OF UPPER HOLES ON PANEL. REPLACED BOTH BOLTS AND WASHERS AND INSTALLED MOVEABLE UPPER PANEL. OPS CHECK GOOD. PANEL MOVES FREELY W/O RESTRICTION MM 52-10-00.