What was found
DURING CLIMBOUT W/FUEL QTY APPROX 129, 000 LBS. LVL 2 "LATERAL FUEL IMBAL" ALERT ON EAD. PERF QRH PROCEDURE, TNK #3 FILL VLVE (IN AUTO MODE) ARMED BUT DIDNT OPEN. FND FUEL IMBLNCE & TTL QTY FLUCT CAUSED BY FAULTY MN TNK 3 QTY INDIC. DFRRED TNK 3 QTY INOP MD11 MEL 28-01-1-2.C/W DMP. BITE UNIT SHWS TNK 3 UNIT 12 FAULT. QTY-31300 LBSR&R FUEL QTY DATA CONTROL UNIT IN REF TO MM 28-41-91-4. TESTED FUEL QTY WITH 12000, 30000, AND 38000 BLS IN #3 TANK REF MM 28-41-00 ALL TESTS PASSED NO FAULTS NOTED THIS CLEARS DEFERRAL ESR 28-41-30-01-5