What was found
*** MAJOR REPAIR *** FAULT: AFT CARGO PIT STA 1500 AND STR 26 LH - STR 25 LH FRAME HAS A DENT. INSTALLED STRINGER CLIP (2E/A) AT AFT CARGO PIT STA 1500 IAW SRM 53-00-07-2R-5. VERIFIED FINAL INSTALLATION OF FRAME REPAIR.JOB COMPLETE
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
*** MAJOR REPAIR *** FAULT: AFT CARGO PIT STA 1500 AND STR 26 LH - STR 25 LH FRAME HAS A DENT. INSTALLED STRINGER CLIP (2E/A) AT AFT CARGO PIT STA 1500 IAW SRM 53-00-07-2R-5. VERIFIED FINAL INSTALLATION OF FRAME REPAIR.JOB COMPLETE