What was found
*SDR FILED OPEN* *MAJOR REPAIR* FAULT: 1 EA DENT FOUND ON LH FRAME STA 800 AT STR 26L REF STEP 31. OUT FOF SEQUENCE. INSPECTED AND VERIFIED SHEAR TIE AND STRINGER IS INSTALLED. JOB COMPLETED. INSPECTION COMPLETED.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
*SDR FILED OPEN* *MAJOR REPAIR* FAULT: 1 EA DENT FOUND ON LH FRAME STA 800 AT STR 26L REF STEP 31. OUT FOF SEQUENCE. INSPECTED AND VERIFIED SHEAR TIE AND STRINGER IS INSTALLED. JOB COMPLETED. INSPECTION COMPLETED.