What was found
INSPECTION TYPE: NA DURING WAI FOUND #2 ENG INLET DENTED AT 2 O'CLOCK POSITION. MAPPED OUT DAMAGE SENT MEASUREMENTS TO ENG NEED HFEC FOR CRACKS 2020250 09/04/23 ACCOMPLISHED HFEC PER NDTSPM CW INTERIOR REPAIR IAW EO MD11-7110-88105-A SECT 6A ITEM REQURIES REPAIR OR REPALCEMENT WITHIN LE PNS ASSIGNED CONTROL # D 812090.REMOVED INLET COWL IN REF TO 54-22-01 [AO 0968045 09/10/23] INSTALLED UPTO STEP (E)(4) IN REF TO AMM 54-22-01 [AO 9168045 09/11/23] ACCOMPLISHED INSTALLATION REMAINING STEPS PER AMM 54-22-01-400-801. THIS CLEARS D812090. ESR: IPC REF 54-62-45-01.