What was found
WTB STRUCTURE - T-CHORD STA 900 HAS CORROSION AT APROX LBL 16 - DOT 07608-005 PERFORMED CUT OUT DAMGED T-CHORD L= 75.5" STA 900 IAW SRM 51-10-02.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
WTB STRUCTURE - T-CHORD STA 900 HAS CORROSION AT APROX LBL 16 - DOT 07608-005 PERFORMED CUT OUT DAMGED T-CHORD L= 75.5" STA 900 IAW SRM 51-10-02.