As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
L PACK TEMP (EICAS C) **OII 1** DMP REVERSED IAW MEL PROCEDURE FOR TROUBLESHOOTING. FOLLOWED FIM 21-51 TASK 877 REV NO:140 AND LH PACK TEMP CONT BITE TEST PERFORMED IAW FIM 21-51-00/101 FIG 103. LH PACK OPS CHECK ALSO GOOD. NO FAULT OBSERVED AND NO HISTORY FOUND IN MAINTENIX. DMP C/OUT AND MANUAL OVERRIDE ACTUATOR MOVED TO CLOSED POSITION. MEL STAYS OPEN.