What was found
EMERGENCY DECLARED, L AFT FUEL PUMP PRESS, R FWD FUEL PUMP PRESS, EQP COOLING OVHT, PROBE HEAT, L AOA, AND EQPT CLG FAN STATUS. EICAS MSG. DECLARED EMERGENCY. VISUALLY INSPECTED C901 IN P31 PANEL FOR LOOSE OR BROKEN LUGS/TERMINALS AS REQUESTED BY TECH SUPPORT, NOTED NO LOOSE OR BROKEN LUGS. C/W SYSTEM TEST OF EQUIPMENT COOLING SYSTEM<BR>REFERENCE: TASK 21-58-00-735-068-011, NO DEFECTS NOTED . NEEDS FURTHER TROUBLESHOOTING