What was found
(APG) REPL L/H WING O/B FLAP O/B FWD HINGE DUE TO HEAVY CORROSION. INST L/H WING O/B FLAP O/B FWD HINGE IN REF TO UPS MD11 AMM 57-53-01-400-801 TW ID: 22-1335 CAL DUE: 26-JUL-2024 TW ID: 19-1220 CAL DUE: 23-APR-2024. RE-INST 3EA BRACKETS & 1EA BELLCRANK & PUSHROD W/FOLLOW UP CABLE & REMOVED CABLE BLOCK IN REF TO UPS MD11 AMM 57-53-01-400-801. CONNECTED #5 SPOILER ACTUATOR I/B HYD LINE & RE-INST BOLT ON ACTUATOR ROD IN REF TO UPS MD11 AMM 27-67-20-400-801 TW ID 23-1027 DUE: 19-APR-2024. PERFORMED OPS & LEACK CHECK OF THE #5 SPOILER ACTUATOR AND HYD LINE, OPS CHECK GOOD, LEAK CHECK GOOD IN REF TO UPS MD11 AMM 27-60-00-860-801 AND 29-00-00-790-801. REINSTALLED HYD LINES AT L/H O/B FLAP O/B FWD HINGE & PERFORMED HYD LEAK CHECK, NO LEAKS NOTED IN REF TO UPS MD11 AMM 57-53-01-400-801 AND 29-00-00-790-801. REVIEWED