*SUPPLEMENTAL SDR* *IFSD* DURING DESCENT INTO TPA, OUT OF FL200,RIGHT ENGINE FLAMED OUT. ACCOMPLISHED QRH & LANDED, "R ENG LP PUMP" STATUS MSG DISPLAYED. DID NOT ATTEMPT RELIGHT. C/W RII 2. CESAR MENDIETA (TECHNICIAN), 28-FEB-2024 23:47 UTC INSTALLED RT ENG LP FUEL PUMP PER AMM 73-11-01 UP TO STEP 3. I. LOW PRESSURE PUMP TEST, REQUIRES PP TESTS 1,2. INSTALLED RT ENG HP FUEL PUMP PER 73-11-03 UP TO STEP 3. I. HIGH PRESSURE PUMP TEST, REQUIRES PP TESTS 1,2. INSTALLED RT ENG FFG PER AMM 73-21-01 UP TO STEP 1 J. FFG INSTALLATION TEST. REQUIRES PP TESTS 1,2,9,,10,11 C/W PP TESTS 1,2,9,10,11, AND 13 IAW MM 71-00-00. OPS AND LK CKS GOOD.