As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
OPERATIONAL CHECK OF INTERIOR EMERGENCY LIGHTS FAILED THE AUTOMATIC ACTIVATION IN EVENT OF DC POWER FAILURE CHECK T/S PER A300 AWM 33-51-03 SUSPECT 490VU MAINTENANCE PANEL 233LT RLY DIM. R&R RELAY IAW ESPM 20-46-50-01. PERFORMED OPS TEST OF EMERGENCY LIGHTING AUTO ACTIVATION IN EVENT OF DC POWER FAIL IAW AMM 33-51-00/501. OPS NORMAL