What was found
CHAFING - SURFACE , NO.4 PYLON DIAGONAL BRACE FORWARD 11:00 POSITION. (REPAIR) MEASURE REWORK AREA DEPTH=0.024", LENGTH=1.1", WIDTH=0.4" IT WAS ALLOWABLE I.A.W SRM 54-51-90-1A-3 FIGURE 101 DETAIL II REV:100. APPLY PROTECTIVE COATING AT REWORK AREA I.A.W SRM 51-20-01-0G REV:100. JOB COMPLETED.