What was found
UPPER CENTER AUXILIARY TANK HAS CRACK LOCATED BETWEEN STA X17 AND X46/STR49. (015-79) ATA 57. INSTALLED 1EA STRINGER SECTION, 2EA "C" ANGLES REPAIR SPLICE, 2EA "Z" ANGLES REPAIR SPLICE AND 2 EA FITTINGS, AT UPPER CTR AUX TANK, STA X17 AND X46 STR 49 PER REF MD-11 SRM 57-10-03-2R-1 REPAIR 1 REV 70. ACCOMPLISHED REPAIR PER MD-11 SRM 57-10-03-2R-1 REPAIR 1, FIGURE 201 (REVISION 70).