What was found
*SDR FILED OPEN* FAULT: 2EA. 1INCH NUT PLATE /CHANNELS, HEAVY CORROSION AND FLAKING STA.1681.8 MAIN DECK FLOOR BEAM RBL45.5 VIEWED FROM THE AFT CARGO PIT 58-14 VERIFIED INSTALLED 2 FLOOR PANEL AND 4 ROLLER FLOOR, 2 SIDEWALL PLATE AND 3 DECK PLATE, 1 TEE, IAW SRM 51-40-02-0G, USING TOOL T10692.