What was found
FOUND M/D FLOOR BEAM CLIP CORROSION AT STA - 2100, LBL 16 (REPLACE). FABRICATE P/N:65B38728-5 I.A.W WS NO.40430 AND BOEING DWG NO.65B38728 SH1 REV.A, PL REV.-, PSDL REV.- AND ORIGINAL PART AS A SAMPLE I.A.W GMM-MTX CH 9.08 REV.7A REQUIREMENT. INSTALL FABRICATED PART I.A.W. SRM 51-40-02-0G REV.100 AND BOEING DWG NO.65B38105 SH11 REV.