What was found
LOWER FWD WING TO BODY SUPPORT IN FRONT OF LEFT ECS BAY DOOR STA 900 HAS EXFOLIATING CORROSION DOT 47-10 VERIFIED INSTALLED NEW T-CHORD IN STRUCTURES ZONE 100 LOWER FWD WING TO BODY FRONT OF LEFT ECS BAY DOOR STA 900 IAW SRM 51-4O-02. MATERIAL USED: RIVET HI-LOCK P/N BACB30NX6K5 BATCH 0004216300, COLLAR P/N BACC30M6 BATCH 0004295539, RIVET P/N BACR15FT6D8C BATCH 0004310225, NUT PLATE P/N NAS1803-3A5 BATCH 0004 316784 AND SEALANT P/N 04-001-0109 BATCH 0004304380. OPEN