What was found
COOROSION AT STA 1200 UNDER FLOORBOARD 242XKF. DOT 140-011.SURFACE HFEC PERFORMED ON BLENDED AREAS ON STA 1200 UNDER FLOORBOARD 242XKF. NO DEFECTS FOUND IAW 51-00-19.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
COOROSION AT STA 1200 UNDER FLOORBOARD 242XKF. DOT 140-011.SURFACE HFEC PERFORMED ON BLENDED AREAS ON STA 1200 UNDER FLOORBOARD 242XKF. NO DEFECTS FOUND IAW 51-00-19.