Service difficulty report · Limit Switch · Airbus A300F4622R

Difficulty date
October 1, 2024
Submitted
October 7, 2024
Operation
Air carrier
Aircraft
N147UP
Make and model
Airbus A300F4622R
Aircraft serial
0830
Aircraft time
24,924 hours, 15,662 cycles
Part
Limit Switch
Condition
Inoperative
Location
Zone 800
Stage of operation
IN
How discovered
V
Nature of condition
O
Precautionary procedure
K

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

MAIN ENTRY DOOR ALARM STARTED SOUNDING AT LEVEL OFF AT FL310. PUSHED DOOR LEVER FORCEFULLY AND ALARM WENT AWAY REMOVED AND REPLACED L1 DOOR LIMIT SWITCH 9WN WITH NEW PART IAW AMM 52-73-13. OPS CHECK GOOD, NO DEFECTS NOTED AT THIS TIME REF AMM 52-73-00 FOR WARNING TEST. DEFERRAL CLEARED, PLACARD REMOVED. PERFORMED RII OF LIMIT SWITCH 9WN INSTALLATION AND DOOR WARNING TEST IAW AMM 52-73-13 AND 52-73-00. OK FOR SERVICE