What was found
FAULT - ITEMS IDENTIFIED BY BUYER - LEFT INBD AFT FLAP - MULTIPLE IMPACT DAMAGES (REPAIR). REMOVE DAMAGE AREA AND SURFACE MOISTURE AND CLEAN THE DAMAGE AREA I.A.W. 747-8F SRM 57-53-01-2R-1 REFER TO SRM 51-70-05-2R-1 PARAGRAPH 5.A.(1), (2) REV.43. REMOVE THE DAMAGE AND TAPER SAND. RECORD THE DAMAGE AREA (DIAMETER:1", 93.5" FROM INBOARD EDGE, 4.5" FROM LEFT HAND AFTER EDGE) I.A.W. 747-8F SRM 57-53-01-2R-1 REFER TO SRM 51-70-05-2R-1 PARAGRAPH 5.A.(3), (4) & (5) REV.43. REMOVE FLUIDS, AND OTHER CONTAMINATION HEAT AREA TO 150°F TO 170°F HOLD FOR 8 HOURS MINIMUM I.A.W. 747-8F SRM 51-70-05-2R-1 PARAGRAPH 5.A.(6). REFER TO SRM 51-20-15-2R-1 REV.43. BOND THE REPAIR PLIES WITH RESIN AND CURE AT 260°F FOR 130 MINUTES WITH MINIMUM VACUUM OF 22 IN/HG I.A.W. 747-8F SRM 51-70-05-2R-1 PARAGRAPH 5.A.(7). THRU PARAGRAPH 5.D REV43. PAPER FINAL REVIEW OK