What was found
DENT FOUND AT IMPACT SPOT JUST ABOVE STRINGER 21 AT STATION 139. FABRICATED REPAIR AND FILLER FROM MATERIAL PO NU SP2550844. DRILLED FASTENER HOLES FOR REPAIR DOUBLER. REF SRM 51-40-08
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DENT FOUND AT IMPACT SPOT JUST ABOVE STRINGER 21 AT STATION 139. FABRICATED REPAIR AND FILLER FROM MATERIAL PO NU SP2550844. DRILLED FASTENER HOLES FOR REPAIR DOUBLER. REF SRM 51-40-08