Service difficulty report · Fire Loop · Airbus A300F4622R
FAA SDR system
- Difficulty date
- January 15, 2025
- Submitted
- January 24, 2025
- Operation
- Air carrier
- Make and model
- Airbus A300F4622R
- Aircraft serial
- 0814
- Aircraft time
- 26,874 hours, 16,876 cycles
- Part
- Fire Loop
- Condition
- Faulted
- Location
- Zone 200
- Stage of operation
- CR
- How discovered
- 9
- Nature of condition
- O
- Precautionary procedure
- O
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
MID 2 MAIN DECK LOOP FAULT (LOOP B) INTERMITTENT R/R 12WU SMOKE DETECTOR PER AMM 26-19-12/401 OPS CHK GOOD. DEFERRAL CLEARED PLACARD REMOVED.R/R 12WU SMOKE DETECTOR PER AMM 26-19-12/401 OPS CHK GOOD. ORIGINAL SUBMISSION DATE: 1/16/2025