What was found
**EMERGENCY DECLARED. ATB, ON CLIMB OUT AFTER V NAV SELECTED R ENGINE COMPRESSOR STALLED AND MAX EGT WAS 892. RAN CHECKLIST AND RETURNED TO SJO OVERTEMPERATURE IS ZONE A PER FIM TASK 71-05 FAULT TREE 824, PERFORM FIM TASK 71-06 FAULT TREE 812 AND REPORT RESULTS OF BLOCK 11 AND BLOCK 13 TO POWERPLANT LIAISON ENGINEERING.