What was found
FAULT - A LOT OF SCREW HOLES OF CEILING SUPPORT CORROSION AT FWD CGO BETWEEN STA 478 TO STA 610, RBL 40 (REPLACE) 1.ACCOMPLISHED REPAIR I.A.W UPS EO-92566-REQ1 REV.1 2.INSTALL FABRICATED PART I.A.W SRM 51-40-02-0G REV.91 AND BOEING DWG NO:453T1001 SH1 REV.A,453T1183 SH4 REV.-,453T1183 SH6 REV.- 3.JOB COMPLETED.