What was found
FAULT - STR - Z600 - R/H WING, I/B FLAP LOWER SKIN, BETWEEN RIB 9 AND 10, AT 1.7 IN I/B OF RIB 10, 2 PUNCTURES AT 14 AND 15 IN OF TRAILING EDGE. DOT 73-036 VERIFIED APPLICATION OF TOP COAT AT EXTERNAL PLATE (DOUBLER) ON R/H WING, I/B FLAP LOWER INNER SKIN, BETWEEN RIB 9A AND 10 FROM 14 AND 15 INCHES OF TRAILING EDGE. IAW A300-600 SRM 57-50-00 PART. 4.E (3) (W).