FAULT: CRACK FOUND IN MIDDLE HOLE ON FR40 RH UPPER TENSION FAST. REPAIR PER A300-600F SRM REV 41 CHAP 57-10-24-201 PARA 5.A, FIG 202 AND FIG 206 SHEET 2 (REPAIR WITH BUSH).UPS CONSIDERS THIS A MINOR REPAIR PER GMM 05.04. CAUTION:THE WORK INSTRUCTIONS CONTAINED WITHIN (OR APPROVED BY) THIS EO CONTAIN RII INSPECT REQUIRE & RII BUY-OFF WHICH MUST BE PERF BY A PROPERLY TRAINED & CURRENTLY AUTHORIZED INDIVIDUAL. TO DETERMINE RII AUTHORIZ, REFER TO THE CURRENT RII AUTHORIZ LIST, SEE CHAPTER 04 OF THE GMM. ACCOMP REPEAT INSPECT PER SRI CHAPTER 57-10-24 PAGE BLOCK 201, TABLE 202. <BR>- FIRST INSPECTION 3300 FC/7200FH FROM TIME OF ADL/REPAIR EMBODIMENT (WHICHEVER VALUE OCCURS FIRST). <BR>- SUBSEQUENT INSPECTION AT INTERVALS OF 3300 FC/7200 FH (WHICHEVER VALUE OCCURS FIRST).<BR>- INSPECTION METHOD REFER TO 57-10-24, PAGE BLOCK 201, FIGURE 208.