As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
FAULT: STR-300-APU AIR INTAKE DOOR ENTRANCE HAS CORROSION. 33-025.REMOVED FWD STRAP SND UPER ANGLE ON APU AIR INTAKE DOOR IAW B757-200 SRM 51-40-02-0G.REMOVE AND REPLACE 1 EACH APU INLET FORWARD STRAP AT STA 1787.45 (P/N: 148N3138-20) PER PRODUCTION DRAWING REQUIREMENTS AND 757-200PF SRM CHAPTER 51 REQUIREMENTS.LOCATED AND DRILLED 1 EA NEW STRAP IAW B757-200-SRM-51-40-05.INSTALLED 1 NEW STRAP IAW B757-200-SRM-51-40-02.