What was found
MDC, BETWEEN FR 78 AND FR 77, LH SIDE, FLOOR STRUCTURE FRAME HAS 2EA CRACKS. DOT 23-002. NEW WEB HAS BEEN INSTALLED IAW A300-600 SRM 51-40-21 AND ALSO THE INTERFAY SEALING HAVE BEEN RESTORED BETWEEN THE SURFACES IAW A300-600 SRM 51-76-10. MATERIALS USED: SEALING P/N:04-001-0109 BATCH# 0004371367 PROTUDING RIVET P/N: MS20470AD5-5 BATCH#0004369861 FLUSH RIVET P/N: MS20426D5-7 BATCH#0004361439. REQUEST OK TO RESTORE TOPCOAT ON THE RIVET'S HEADS. APPROVED