What was found
CREW DOOR, FLOOR AREA, NEAR C15A UNDER PANEL 221FF, STRIP SUPPORT HAS A CRACK DOT 103-25 INSTALED NEW ANGLE STRIP SUPPORT FOR STRUCTURE BELOW PANEL 221FF IAW A300-600 SRM 51-40-21.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CREW DOOR, FLOOR AREA, NEAR C15A UNDER PANEL 221FF, STRIP SUPPORT HAS A CRACK DOT 103-25 INSTALED NEW ANGLE STRIP SUPPORT FOR STRUCTURE BELOW PANEL 221FF IAW A300-600 SRM 51-40-21.