What was found
FAULT-STR-ZONE 200. UPPER FUSELAGE (CROWN), STA 1200-1220 AT S-L3 PREVIOUS BLEND OUT AROUND FASTENER NOT LISTED ON MAPPING.REMOVED PAINT ON PREVIOUS BLEND OUT AREA WITH PAINT STRIPPERS IAW 757-200PF AMM 51-21-01-157-111.ACCOMPLISHED STEP 1 OF PRELIMINARY 1, E.A. #: 757-5360-27-A4010, REMOVED 1EA FASTENER IN THE BLENDED AREA PER 757-200PF SRM 51-40-02.ACCOMPLISHED STEP 2 OF PRELIMINARY 1, E.A. #: 757-5360-27-A4010. ACCOMPLISHED REPAIR PER EO-94177-REQ1 AND VT-MAE EA 757-5360-27-A4010